Digital Power Meter For Harmonic Analysis Snd Standby Power Measurement
0.15 Class Digital Power Meter
,Harmonic AC DC Power Analyzer
,Standby Power Consumption Power Meter
Parameter | PM9200 |
Bandwidth | DC,0.5Hz~2KHz |
Input model | Voltage and Current are floating input |
Accuracy | (0.2%) |
Display update | Display refresh cycle 0.1s~5s |
Line filtering | cut-off frequency 500Hz |
A/D Converter | sampling period 70μS,24bits,voltage and current simultaneous sampling |
Input Impedance | Voltage input impedance is 2MΩ, current input impedance is 0.5Ω, High-grade is 4mΩ. The input impedance of the input terminal of External sensor signal Changes according to the change of input voltage.10V: 100kΩ,2V: 20 kΩ. |
Zero mode | Calibrate the zero point each time when the range is changed or the measurement mode is changed |
Measurement mode | RMS VOLTAGE MEAN AC DC |
The power consumption | < 10VA |
Power supply of meter | AC 100V~240V 45~440Hz DC 100V~300V |
Communication Interface | USB,RS-232/485(standard), Ethernet(optional) |
Parameter | Measuring Range | Error | Min. resolution |
Voltage | (0.5~600)V | DC ±(read 0.1% + range 0.2% ) 0.5 Hz ≤ f< 45 Hz ±(read 0.1% + range 0.2% ) 45 Hz ≤ f ≤ 66 Hz ±(read 0.1% + range 0.1 % ) 66 Hz < f ≤ 1 kHz ±(read 0.1% + range 0.2 % ) 1 k Hz < f ≤ 2 kHz ±(read 0.15% + range 0.3% ) | 0.001V |
Current | 0.05mA~45A | 0.001A | |
Active power | U*I*PF | DC ±(read 0.1% + range 0.2% ) 0.5 Hz ≤ f< 45 Hz ±(read 0.3% + range 0.2% ) 45 Hz ≤ f ≤ 66 Hz ±(read 0.1% + range 0.1 % ) 66 Hz < f ≤ 1 kHz ±(read 0.2% + range 0.2 % ) 1 k Hz < f ≤ 2 kHz ±(read 0.2% + range 0.3 % ) | 0.001mW |
Power factor | |||
0.01~1 | 0.5 Hz ≤ f≤ 66 Hz ±0.01 66 Hz < f ≤ 1 kHz ±0.02 1 k Hz < f ≤ 2 kHz ±0.05 | 0.001 | |
Frequency | 0.5Hz~2KHz | 0.1% | 0.001Hz |
Electric energy accumulation | 0~999999MWh 0~-99999MWh | DC ±(read 0.1% + range 0.2% ) 0.5 Hz ≤ f< 45 Hz ±(read 0.3% + range 0.2% ) 45 Hz ≤ f ≤ 66 Hz ±(read 0.1% + range 0.1% ) 66 Hz < f ≤ 1 kHz ±(read 0.2% + range 0.2% ) 1 k Hz < f ≤ 2 kHz ±(read 0.2% + range 0.3% ) | 0.0001mWh |
Total ah | 0~999999MAh 0~-99999MAh | DC ±(read 0.1% + range 0.2% ) 0.5 Hz ≤ f< 45 Hz ±(read 0.1% + range 0.2% ) 45 Hz ≤ f ≤ 66 Hz ±(read 0.1% + range 0.1% ) 66 Hz < f ≤ 1 kHz ±(read 0.1% + range 0.2% ) 1 k Hz < f ≤ 2 kHz ±(read 0.15%+ range 0.3% ) | 0.0001mAh |
Electric energy timing | 99999h | ± 2s/H | 1s |
Harmonic | 1~50times Accuracy: B class IEC61000-4-7 | Maximum times of fundamental frequency analysis 10Hz~65Hz 50 65Hz~100Hz 32 100Hz~200Hz 16 200Hz~400Hz 8 | 0.01 |


Meet the ICE.62301-2016 standard. And have RS232/RS485,USB, Ethernet communication interface.
Product DescriptionParameterPM9200BandwidthDC,0.5Hz~2KHzInput modelVoltage and Current are floating inputAccuracy(0.2%)Display updateDisplay refresh cycle 0.1s~5sLine filteringcut-off frequency 500HzA/D Convertersampling period 70μS,24bits,voltage and current simultaneous samplingInput ImpedanceVolt...